-40%
ELEGRP 20 Amp GFCI Outlet, 5-20R GFI Dual Receptacle, TR Tamper Resistant and...
$ 12.62
- Description
- Size Guide
Description
Brand New ELEGRP 20 Amp GFCI Outlet, 5-20R GFI Dual Receptacle, TR Tamper Resistant and WR Weather Resistant, Self-Test Ground Fault Circuit Interrupters, Wall Plate Included, UL Listed (1 Pack, Matte Black)Manufacturer model:
G1920TW-BL
Innovative Dual Protection System Features twin solenoid and double Silicon Controlled Rectifier (SCR), ensuring an always-on GFCI protection to ground fault, which doubles the service life of GFCI as an added layer of protection. UL & CUL Listed.
Patented Self-Test Every 5 Seconds The GFCI outlet automatically conducts self-test (auto-monitor) every 5 seconds to ensure the GFCI is continually working to protect people from electrocution, which exceeds the UL standards of self-test frequency of 3 hours.
Tamper Resistant & Weather Resistant Automatic shutter system prevents young children from inserting unwanted objects into the outlets. Constructed with advanced UV stabilized engineering to provide superior corrosion, temperature, and UV resistance, preventing from discoloration and aging, ideal for outdoor use (recommend to install with outdoor protective covers).
Safe Enough Strictly tested as per or exceeds UL943 & UL498 requirements. Innovated Reset-Disable System ensures the GFCI cannot be reset once it reaches the end of life. Reversed Wiring Prevention makes it no power at the GFCI outlet and downstream if the LINE / LOAD is miswired. Constructed with premium high-impact resistant thermoplastic materials and rational structure design, ensures superior strength and durability.
Easy Installation All screws have been loosened for ease of installation, there's no need to loosen the screws counterclockwise before wiring. Works with 12 or 14 AWG for side wire and back wire. Replace an existing outlet in as short as 10 minutes. A screw-less wall plate and complete installation instructions included. Compatible with all electrical boxes, decora devices and wall plates.
Description
Product Description
Durable and Long Service Life
The GFCI outlet is designed to withstand 20KV, 10KA voltage surge, while UL943 only requires 6KV, 10KA.
YOUR SAFETY WORTH MORE
A GFCI outlet is different from conventional outlets. In the event of a ground fault, our GFCI will trip and quickly stop the flow of electricity to prevent serious injury.
Reversed Wiring Prevention
To prevent the GFCI protection being disabled by reversed wiring, there will be no power at the GFCI outlet and downstream if the LINE / LOAD is miswired. (in this case the green LED light won’t be OFF)
Power Denial System
Innovated Reset-Disable System ensures the GFCI cannot be reset once it reaches the “end of life”.
Patented Self Test Every 5 Seconds
The GFCI outlet automatically conducts self-test (auto-monitor) every 5 seconds to ensure the GFCI is continually working to protect people from electrocution, which exceeds the UL standards of self-test frequency of 3 hours.
BUILT-IN TAMPER RESISTANT SHUTTERS IN OUTLET
Tamper resistant shutters to keep children from electrocution, making your home a safer place. Shutter mechanism inside the receptacle blocks access to the contacts unless a two-or-three-prong plug is inserted, helping ensure hairpins, keys, etc., can't be inserted in.
Please note:
Tamper resistant receptacles have a safety gate in the outlet to prevent unwanted objects being inserted. The outlet can be a bit difficult to plug into the first few times. This will become easier after long-time use.
Press the RESET button fully to restore power to the GFCI outlet after installation
IMPORTANT
After installation, please press the RESET button fully to restore power to the GFCI outlet. The RESET button should stay in. The LED indicator will illuminate green in color.
The GFCI outlet only accept 12 or 14 AWG solid copper or copper-clad wire.
Do not install this GFCI outlet on a circuit that powers life support equipment because if the GFCI trips it will shut down the equipment.
For outdoor use or in damp/wet locations, please choose Weather Resistant (marked with WR) GFCI outlet and install it with a weather-proof outlet cover that will keep both the outlet and plug face dry.
PRODUCT SPECIFICATION
Input Rating:
125V, 60Hz
GFCI Rated Current:
20 AMP
Residual Operating Current:
4mA~6mA
Wiring Type:
Side Wire or Back Wire
Operating Temperature:
-31 to 150.8℉ (-35℃ to 66℃)
Product Size:
4.05x1.68x1.50" (103x42.7x38.1mm)
Remark:
Screwless wall plate included
15A TR
15A TR WR
20A TR
20A TR WR
Rating
15A 125V
15A 125V
20A 125V
20A 125V
Tamper Resistant
✓
✓
✓
✓
Weather Resistant
✓
✓
Color
Black
Black
Black
Black
Remark
Screwless wall plate include
Screwless wall plate include
Screwless wall plate include
Screwless wall plate include
15A TR
15A TR WR
20A TR
20A TR WR
Rating
15A 125V
15A 125V
20A 125V
20A 125V
Tamper Resistant
✓
✓
✓
✓
Weather Resistant
✓
✓
Color
Black
Black
Black
Black
Remark
Wall plate include
Wall plate include
Wall plate include
Wall plate include
Shipping and Handling
Please allow 5-7 business days for the package to arrive, regardless of buyer location within the US.
We will provide an online tracking number to you once the item has been shipped.
It may take a few business days for our automated system to process the tracking number onto eBay. However, this will not affect the shipping times.
Return Policy
All our products are brand new and sealed. All items qualify for returns within 30 days of receipt.
Feedback
We take our reputation seriously. If you have any questions or concerns, please contact us and we will respond back to your message within 24 hours.